Quantities, straight from the drawing.
Upload a DXF floor plan from AutoCAD. Tekton measures the rooms, doors and windows from the lines themselves, ready to price room by room.
As drawn
Every line on every layer: walls, glass, doors, beds, a dining table, the WC. 218 lines on 5 layers, read in millimetres.
Walls
Furniture and fittings set aside. What remains bounds space: walls found in pairs at 230 and 115 mm.
Openings
Every gap in a wall measured jamb to jamb: 6 doors and 7 windows, each to the millimetre.
Rooms
Rooms closed from the drawn lines alone, with nothing bridged by guesswork: 7 rooms, 83.96 m² of floor.
Quantities
Floor, perimeter and wall area for each room. Plaster and paint come to 2,710 sq ft once every door and window is taken off.
What Tekton does
Every estimate starts with someone measuring the drawing by hand, room by room and door by door. Tekton takes those measurements from the lines the architect already drew, and shows you where each one came from.
The schedule it hands back.
For the same flat, at a 3 m ceiling. Wall area is net of every door and window, taken off each room it opens onto.
| Room | Floor m² | Floor sq ft | Perimeter ft | Wall sq ft |
|---|---|---|---|---|
| Toilet 1 | 4.04 | 43.5 | 26.8 | 239 |
| Kitchen | 13.44 | 144.7 | 49.9 | 451 |
| Bedroom 2 | 12.96 | 139.5 | 47.2 | 421 |
| Passage | 10.08 | 108.5 | 43.3 | 352 |
| Bedroom 1 | 15.12 | 162.8 | 51.2 | 460 |
| Living and Dining | 24.00 | 258.3 | 64.3 | 540 |
| Toilet 2 | 4.32 | 46.5 | 27.6 | 247 |
| Total | 83.96 | 903.8 | 310.3 | 2,710 |
| Width mm | Count |
|---|---|
| 750 | 2 |
| 900 | 3 |
| 1000 | 1 |
| Width mm | Count |
|---|---|
| 600 | 2 |
| 1500 | 2 |
| 1800 | 2 |
| 2400 | 1 |
What it will not guess.
Units are checked, not trusted.
A DXF header often names the wrong unit. Tekton measures the walls in each candidate unit and overrules the header only when the walls disagree with it clearly.
A door is a gap in a wall.
Width is taken from the wall: the narrowest distance between jambs, across the full thickness. Swing, double, sliding or folding, the door symbol only says that something fills the gap.
Rooms close from drawn lines.
No gap is bridged by a threshold or a guess. A line that stops a few millimetres short of the one it was meant to meet is carried on to it, and nothing further.
Voids are not floor.
A shaft or a double-height void marked with a cross is held out of the rooms, shown on the plan, and never billed as floor.
Unsure is shown, not filled in.
Where a door’s jambs cannot be measured, the door is shown on the plan without a width. It is not given a standard size and passed off as measured.
The whole method, with its known limits, is on the method page.
Then price it, room by room.
Choose the work each room needs. Every line bills the quantity its trade bills, and shows how it got there.
- Flooring
- Screed and tile over the floor plate, tile with 5% for cutting. Skirting along the perimeter.
- Walls
- Plaster, putty, primer and paint over the wall area, with every door and window taken off each room it opens onto.
- Dado
- Wall tiling to 7 ft, not to the ceiling.
- Waterproofing
- Floor, walls to 1.2 m, the shower zone 0.9 m higher, and every threshold. Ticked one by one, each with 10% wastage.
- Ceiling
- False ceiling and ceiling paint over the floor plate.